Amanzi ReVive™ mine water treatment plant in the
Western Witwatersrand Basin

Project Summary
Amanzi ReVive™ mine water treatment plant in the Western Witwatersrand Basin (Krugersdorp / Randfontein area, Gauteng Province, South Africa) - an area where acid mine drainage (AMD) and decant are the most sensitive environmental and socio-political issues in the region.
• Problem: The Western Basin is the only one of the three Witwatersrand basins with virtually uncontrolled acidic water drainage (into the Tweelopies Spruit estuary feeder). The current HDS station at Rand Uranium (TCTA / Rand) is designed for 30–35 million liters per day and only neutralizes water, without removing sulfates and salts; decantation continues during the peak rainy season.
• Solution: Amanzi ReVive™ containerized treatment module (capacity 250–500 m³/day, scalable to 10–1300 m³/day per module), placed directly at the decant/discharge point, with neutralization of heavy metals, sulfates and pathogens, closed recirculation cycle and neutralized sludge of hazard class V.
• The key technical issue of the pilot: confirmation of the removal of radionuclides (uranium) - the main regulatory barrier to the application of any cleanup technologies in the Western Basin - and compliance with DWS discharge standards (General / Special Limit, National Water Act).
• Business model: pilot with transition to commercial operation under one of three partnership schemes - equipment supply, localization or joint ownership of the facility (WaaS).
Justification for the choice of site
Witwatersrand basin was selected based on a combination of criteria:
• The only basin with persistent decantation incidents: overflows from the mine space are recorded at point 18 Winze (near the Sibanye-Stillwater sites) and at the Krugersdorp Reserve; the flow goes into the Tweelopies Spruit and Rietspruit streams.
• Maximum regulatory and media sensitivity: beyond the decant zone lies the Cradle of Humankind (a UNESCO site), residential areas, and dolomite karst, vulnerable to groundwater pollution. Any pilot project here receives priority attention from DWS, TCTA and public organizations.
• Availability of existing infrastructure: HDS station at Rand Uranium, DRDGold and Sibanye-Stillwater engineering sites, power supply and access roads, which reduces the CAPEX of the pilot piping.
• Excess water in the mine space (more than 30 million l/day per pumping) is a guaranteed flow of runoff for testing all year round.
• Interest of target partners: DWS / TCTA are openly seeking alternative and cost-effective technologies (including through the Rand Uranium platform for technology providers).